A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the
A vulnerability has been identified in Mendix SAML (Mendix 7 compatible) (All versions >= V1.17.3 < V1.18.0), Mendix SAML (Mendix 7 compatible) (All versions >= V1.16.4 < V1.17.3), Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.4.0), Mendix SAML (Mendix 8 compatible) (All versions >= V2.2.0 < V2.3.0), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.1 < V3.6.1), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.1.9 <…
An improper certificate validation vulnerability [CWE-295] in FortiOS 6.2 all versions, 6.4 all versions, 7.0.0 through 7.0.10, 7.2.0 and FortiProxy 1.2 all versions, 2.0 all versions, 7.0.0 through 7.0.9, 7.2.0 through 7.2.3 may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the vulnerable device and the remote FortiGuard's map server.
A access of uninitialized pointer vulnerability [CWE-824] in Fortinet FortiProxy version 7.2.0 through 7.2.3 and before 7.0.9 and FortiOS version 7.2.0 through 7.2.4 and before 7.0.11 allows an authenticated attacker to repetitively crash the httpsd process via crafted HTTP or HTTPS requests.
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC S7-PM (All versions), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database…
A plaintext storage of a password vulnerability [CWE-256] in FortiSIEM 6.7 all versions, 6.6 all versions, 6.5 all versions, 6.4 all versions, 6.3 all versions, 6.2 all versions, 6.1 all versions, 5.4 all versions, 5.3 all versions may allow an attacker able to access user DB content to impersonate any admin user on the device GUI.
An insertion of sensitive information into log file vulnerability in Fortinet FortiOS 7.2.0 through 7.2.4 and FortiProxy 7.0.0 through 7.0.10. 7.2.0 through 7.2.1 allows an attacker to read certain passwords in plain text.
Multiple improper neutralization of special elements used in an os command ('OS Command Injection') vulnerabilties [CWE-78] in Fortinet FortiADCManager version 7.1.0 and before 7.0.0, FortiADC version 7.2.0 and before 7.1.2 allows a local authenticated attacker to execute arbitrary shell code as `root` user via crafted CLI requests.
Improper Input Validation vulnerability in PHOENIX CONTACT FL/TC MGUARD Family in multiple versions may allow UDP packets to bypass the filter rules and access the solely connected device behind the MGUARD which can be used for flooding attacks.
Use of insufficiently random values vulnerability in User Management Functionality in Synology DiskStation Manager (DSM) before 7.2-64561 allows remote attackers to obtain user credential via unspecified vectors.