Jettison before v1.5.2 was discovered to contain a stack overflow via the map parameter. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted string.
A Denial-of-Service (DoS) vulnerability was discovered in the fsicapd component used in WithSecure products whereby the service may crash while parsing ICAP request. The exploit can be triggered remotely by an attacker.
A vulnerability has been identified in Mendix Email Connector (All versions < V2.0.0). Affected versions of the module improperly handle access control for some module entities. This could allow authenticated remote attackers to read and manipulate sensitive information.
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions < V3.5.5), APOGEE PXC Series (P2 Ethernet) (All versions < V2.8.20), TALON TC Series (BACnet) (All versions < V3.5.5). A low privilege authenticated attacker with network access to the integrated web server could download sensitive information from the device containing user account credentials.
A vulnerability has been identified in JT2Go (All versions), Teamcenter Visualization V13.2 (All versions < V13.2.0.12), Teamcenter Visualization V13.3 (All versions < V13.3.0.8), Teamcenter Visualization V13.3 (All versions >= V13.3.0.8), Teamcenter Visualization V14.0 (All versions < V14.0.0.4), Teamcenter Visualization V14.0 (All versions >= V14.0.0.4), Teamcenter Visualization V14.1 (All versions < V14.1.0.6). The CCITT_G4Decode.dll contains an out of bounds read vulnerability when…
A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP200) (All versions), SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions), SIPROTEC 5 6MD86 devices (CPU variant CP200) (All versions), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions), SIPROTEC 5 7KE85 devices (CPU variant CP200) (All versions), SIPROTEC 5 7KE85 devices (CPU variant CP300)…
A vulnerability has been identified in PLM Help Server V4.2 (All versions). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link.
The Samsung TV (2021 and 2022 model) smart remote control allows attackers to enable microphone access via Bluetooth spoofing when a user is activating remote control by pressing a button. This is fixed in xxx72510, E9172511 for 2021 models, xxxA1000, 4x2A0200 for 2022 models.
A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g.,…
Resque Scheduler version 1.27.4 is vulnerable to Cross-site scripting (XSS). A remote attacker could inject javascript code to the "{schedule_job}" or "args" parameter in /resque/delayed/jobs/{schedule_job}?args={args_id} to execute javascript at client side.