Summary:Product: AndroidVersions: Android SoCAndroid ID: A-204686438
In updatePackageMappingsData of UsageStatsService.java, there is a possible way to bypass security and privacy settings of app usage due to an unusual root cause. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-11 Android-12Android ID: A-197399948
In clear_data_dlg_text of strings.xml, there is a possible situation when "Clear storage" functionality sets up the wrong security/privacy expectations due to a misleading message. This could lead to local information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12Android ID: A-193890833
Tokheim Profleet DiaLOG 11.005.02 is affected by SQL Injection. The component is the Field__UserLogin parameter on the logon page.
Nokia BTS TRS web console FTM_W20_FP2_2019.08.16_0010 allows Authentication Bypass. A malicious unauthenticated user can get access to all the functionalities exposed via the web panel, circumventing the authentication process, by using URL encoding for the . (dot) character.
A CWE-669: Incorrect Resource Transfer Between Spheres vulnerability exists that could cause data exfiltration and unauthorized access when accessing a malicious website. Affected Product: spaceLYnk (V2.6.1 and prior), Wiser for KNX (V2.6.1 and prior), fellerLYnk (V2.6.1 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
This affects the package fastify-multipart before 5.3.1. By providing a name=constructor property it is still possible to crash the application. **Note:** This is a bypass of CVE-2020-8136 (https://security.snyk.io/vuln/SNYK-JS-FASTIFYMULTIPART-1290382).
A CWE-20: Improper Input Validation vulnerability exists that could cause a Denial of Service when a crafted packet is sent to the controller over network port 1105/TCP. Affected Product: Modicon M218 Logic Controller (V5.1.0.6 and prior)