lock order inversion in transitive grant copy handling As part of XSA-226 a missing cleanup call was inserted on an error handling path. While doing so, locking requirements were not paid attention to. As a result two cooperating guests granting each other transitive grants can cause locks to be acquired nested within one another, but in respectively opposite order. With suitable timing between the involved grant copy operations this may result in the locking up of a CPU.
XAPI open file limit DoS It is possible for an unauthenticated client on the network to cause XAPI to hit its file-descriptor limit. This causes XAPI to be unable to accept new requests for other (trusted) clients, and blocks XAPI from carrying out any tasks that require the opening of file descriptors.
До конференции SmartData осталось меньше недели, и мы делимся с Хабром её полной программой. В ней — доклады об архитектуре дата-платформ, обработке данных, хранилищах больших данных и не только. Спикеры как сравнивают уже готовые решения, так и рассказывают о собственных…
Начали с большого старого проекта на руби, поддерживаемого аутсорсерами, а оставили отлично документированный и покрытый тестами проект с техническим директором и внутренней командой разработки. Это честный рассказ о проекте длиною в год.Вебиум — онлайн-школа для…
Двигатели, используемые в робототехнических устройствах, в составе прецизионных приводов станков ЧПУ, опорно-поворотных систем слежения, манипуляторов и других устройств для выполнения своих задач должны иметь очень плавный ход без рывков и пульсаций. Однако стандартной…
Привет, Хабр! Сегодня мы расскажем об интересных задачах соревнования Fusion Brain Challenge с международной конференции AIJ 2021 по искусственному интеллекту, нейросетям и смежным темам. Цель проведения ― собрать на одной площадке представителей международных организаций, бизнеса,…
A vulnerability has been identified in SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All versions < V3.10), SICAM P850 (All…
A vulnerability has been identified in JTTK (All versions < V11.1.1.0), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The JTTK library is vulnerable to an uninitialized pointer reference vulnerability while parsing specially crafted JT files. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-16973)
A vulnerability has been identified in Industrial Edge Management (All versions < V1.5.1). The affected software does not properly validate the server certificate when initiating a TLS connection. This could allow an attacker to spoof a trusted entity by interfering in the communication path between the client and the intended server.
A vulnerability has been identified in Desigo PXM30-1 (All versions < V02.20.126.11-41), Desigo PXM30.E (All versions < V02.20.126.11-41), Desigo PXM40-1 (All versions < V02.20.126.11-41), Desigo PXM40.E (All versions < V02.20.126.11-41), Desigo PXM50-1 (All versions < V02.20.126.11-41), Desigo PXM50.E (All versions < V02.20.126.11-41), PXG3.W100-1 (All versions < V02.20.126.11-37), PXG3.W100-2 (All versions < V02.20.126.11-41), PXG3.W200-1 (All versions < V02.20.126.11-37),…