Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions and Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions allows a remote unauthenticated attacker to login to the product by replay attack.
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric MELSEC iQ-F series FX5U(C) CPU all versions and Mitsubishi Electric MELSEC iQ-F series FX5UJ CPU all versions allows a remote unauthenticated attacker to disclose a file in a legitimate user's product by using previously eavesdropped cleartext information and to counterfeit a legitimate user's system.
n Spring Framework versions 5.3.0 - 5.3.16 and older unsupported versions, it is possible for a user to provide a specially crafted SpEL expression that may cause a denial of service condition.
In Spring Cloud Function versions 3.1.6, 3.2.2 and older unsupported versions, when using routing functionality it is possible for a user to provide a specially crafted SpEL as a routing-expression that may result in remote code execution and access to local resources.
A Spring MVC or Spring WebFlux application running on JDK 9+ may be vulnerable to remote code execution (RCE) via data binding. The specific exploit requires the application to run on Tomcat as a WAR deployment. If the application is deployed as a Spring Boot executable jar, i.e. the default, it is not vulnerable to the exploit. However, the nature of the vulnerability is more general, and there may be other ways to exploit it.
A buffer overflow vulnerability found in the UniFi Door Access Reader Lite’s (UA Lite) firmware (Version 3.8.28.24 and earlier) allows a malicious actor who has gained access to a network to control all connected UA devices. This vulnerability is fixed in Version 3.8.31.13 and later.
A blind self XSS vulnerability exists in RocketChat LiveChat <v1.9 that could allow an attacker to trick a victim pasting malicious code in their chat instance.
Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.
Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges
When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.