Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in GetLatestDemandNode and GetDemandAnalysisData. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerPage_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to path traversal attacks, which may allow an attacker to write arbitrary files to locations on the file system.
An issue was discovered in SaltStack Salt in versions before 3002.8, 3003.4, 3004.1. Salt Masters do not sign pillar data with the minion’s public key, which can result in attackers substituting arbitrary pillar data.
An issue was discovered in SaltStack Salt in versions before 3002.8, 3003.4, 3004.1. A minion authentication denial of service can cause a MiTM attacker to force a minion process to stop by impersonating a master.
An issue was discovered in SaltStack Salt in versions before 3002.8, 3003.4, 3004.1. Job publishes and file server replies are susceptible to replay attacks, which can result in an attacker replaying job publishes causing minions to run old jobs. File server replies can also be re-played. A sufficient craft attacker could gain root access on minion under certain scenarios.
An issue was discovered in SaltStack Salt in versions before 3002.8, 3003.4, 3004.1. When configured as a Master-of-Masters, with a publisher_acl, if a user configured in the publisher_acl targets any minion connected to the Syndic, the Salt Master incorrectly interpreted no valid targets as valid, allowing configured users to target any of the minions connected to the syndic with their configured commands. This requires a syndic master combined with publisher_acl configured on the Master-of-Masters,…
Guest driver might execute HW commands when shared buffers are not yet allocated, potentially leading to a use-after-free condition.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerDialog_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
A local attacker, as a different local user, may be able to send a HTTP request to 127.0.0.1:10000 after the user (typically a developer) manually invoked the ./tools/run-dev-server script. It is recommended to upgrade to any version beyond 24.2